MENU
 

Utility & Telecom Power Inverter

utility & telecom power inverter

24/48/120 VDC,  Rack & Floor Mount Models

Utility & Telecom Power Inverter, a highly efficient and cost effective solution for AC powered devices. The space saving rack mount inverters are well suited for sensitive telecommunication and data processing installations and can power more demanding loads such as motors, rectifiers switch mode power supplies and nonlinear loads.

Main Features of the Utility & Telecom Power Inverter

  • True On-line Technology for Maximum Power Protection
  • True “Zero Break” Fully Rated Solid State Static Transfer Switch Standard
  • Pure Sine Wave Output
  • Transistor Power Block Technology
  • 20-Year Design Life
  • CopperWound Transformers
  • Easy Access Front Door
  • Input to Output Isolation
  • Less than 1% output THD
  • Low Audible Noise
  • Short Circuit Protection
  • Mounts in Standard 19” or 23” Rack
  • Handles 5:1 Crest Factor Loads
  • DC Input Circuit Breaker
  • AC Output Circuit Breaker
  • Form “C” Alarm Interface Contacts
  • ANSI 61 Gray Powder Coat Finish
  • Built to Meet UL1778, NEMA, NEC, ANSI and FCC Standards

Options

  • Multiple Voltage Outputs Available
  • 50Hz/60Hz Models
  • External Maintenance Bypass Switch
  • Floor Mount Kit
  • Direct Inverter (No Static Switch)
  • Customizable Designs for Unique Applications

UTILITY & TELECOM POWER INVERTER

DCINPUT
Model 1kva 2kva 3kva 5kva 7.5kva 10kva
Nominal DC Voltage (V) 24 24 48 48 120 24 48 120 120 48 120
Max Current (A) 46 92 46 69 28 230 115 46 69 230 92
Protection (Breaker Amps) 60 100 60 80 32 250 160 60 80 250 125
Noise Feedback Less than 32dBrnC
 
AC OUTPUT
Power Rating  1kva  1.5kva 2kva 2.5kva 3kva 5kva 7.5kva 10kva
Nominal Voltage  120VACStandard, 100/127/200/208/220/230/240Optional
Frequency 50 / 60Hz
Frequency Stability ±0.1%Internal Crystal Controlled
Acceptable Bypass Synchronization ± 2Hz
Regulation ±2%over entire input voltage and load range
Waveform Pure Sine Wave
Crest Factor  5:1
Harmonic Distortion < 1%with linear load from.8 leading to .8 lagging power factor
Overload 125%for 10min, 150%for 1min
Protection Circuitry Circuit Breaker and Fusing
 
AC BYPASS INPUT
Voltage (V) 120VACStandard, other voltages available as an option
Frequency (Hz) 50 / 60Hz (Bypass freq.mustmatch output freq.)
ENVIRONMENT
Operating Temperature 32°F to 122°F (0°C to 50°C)
Ventilation Forced Air (front to back)
Heat Dissipation (BTU/Hr) 512 768 1,024 1,280 1,535 2,559 3,839 5,118
Humidity  0 – 95%non-condensing
Audible Noise < 50 dB(A)Scale@1meter
Operational Altitude  5,000 ft. (1,500m)