MajorPower.Com: Powerware Ferrups Rackmount Series convert power from almost any AC source into computer grade power and eliminate harmful harmonic currents from entering a building's wiring, where they can disrupt computer operations Product List | Order | Contact Us
MajorPower.Com: Powerware Ferrups Rackmount Series convert power from almost any AC source into computer grade power and eliminate harmful harmonic currents from entering a building's wiring, where they can disrupt computer operations
Search:
MajorPower.Com: Powerware Ferrups Rackmount Series convert power from almost any AC source into computer grade power and eliminate harmful harmonic currents from entering a building's wiring, where they can disrupt computer operations MajorPower.Com: Powerware Ferrups Rackmount Series convert power from almost any AC source into computer grade power and eliminate harmful harmonic currents from entering a building's wiring, where they can disrupt computer operations MajorPower.Com: Powerware Ferrups Rackmount Series convert power from almost any AC source into computer grade power and eliminate harmful harmonic currents from entering a building's wiring, where they can disrupt computer operations Tel: 514.369.4919 Fax: 514.369.4817

  Home > UPS > Powerware > Ferrups RM

Email this page MajorPower.Com: Powerware Ferrups Rackmount Series convert power from almost any AC source into computer grade power and eliminate harmful harmonic currents from entering a building's wiring, where they can disrupt computer operations
Powerware Ferrups Rackmount Series

Powerware Ferrups Rackmount Features
  • Active Voltage Regulation converts power from almost any AC source into computer grade Power
  • Eliminates harmful harmonic currents from entering a building's wiring, where they can disrupt computer operations
  • Enhanced diagnostics initiates automatic startup and scheduled tests on the logic board, battery and other critical systems
  • Provides regulated output voltage without drawing power from batteries keeping the batteries fully charged from unexpected blackouts
  • Complete offering of power management software included to ensure data integrity
  • 2-year Limited Warranty
  • 500 VA - 18 kVA Rating
  • 120/208/240 & 220/230 VAC Voltage
  • 60 or 50 Hz Frequency
  • Rackmount (Tower Available)
Powerware Ferrups Rackmount
Powerware Ferrups Rackmount Brochure Download
  Ferrups Rackmount 60Hz Specs
  Ferrups Rackmount 50Hz Specs
 

Powerware Ferrups Rackmount Specifications
Operation
Nominal Input Voltage 120/208/240, 60Hz (220/230, 50Hz Available)
Input Voltage Range +15%, -20%
Nominal Output Voltage 120/208/240, 60Hz (220/230, 50Hz Available)
Output Voltage Regulation ±3% for input voltages + 15% to =20%
Output Voltage Waveform Sine Wave
Output Voltage THD 5% or less at rated kW load
Overload Capacity 150% surge & 125% for 10 minutes online; 150% & 110% for 10 minutes on inverter
Transfer Time 0 ms
Lightning, Surge and Noise Protection 2000: 1 spike attenuation using ANSI/IEEE C62.41 and C62.45 Category A and Category B tests. Common Mode ->120 dB.Normal Mode ->60dB
Safety Certification UL, CSA, cUL, CE
EMI Compliance Hot-swappableFCC Class A
Testing Standards ANSI/EEE C62.41 (1980); ANSI/EEE C62.45 (1987); IEC 801-2, 801-4, 801-5
Communication RS-232 serial port (DB-25), plus contact closures
Environmental
Operating Temperature 0 to 40°C
Storage Temperature -20° to + 60°C
Relative Humidity 5 to 95% without condensation
Altitude 3050 m (10,000 ft) Maximum

Powerware Ferrups Rackmount Model Selection Guide
Model Number FES 850VA FES 1.15kVA FES 1.4kVA FER 1.8kVA FER 2.1kVA FER 3.1kVA FER 4.3kVA FER 7kVA
Capacity (kVA/kW) .8/.6 1.15/.8 1.4/1 1.8/1.25 2.1/1.5 3.1/2.2 4.3/3 7/5
Dimensions (HxWxD)
inches/mm
9.75 x 16 x 21.25
248 x 406 x 540
9.75 x 16 x 26.25
248 x 406 x 667
16 x 16 x 26.25
483 x 406 x 667
Front Panel (HxW)
inches/mm
10.5 x 19 / 267 x 483 19.25 x 19
489 x 483
Battery Pack (HxWxD) inches/mm Internal 8.3 x 16.25 x 24.25
211 x 413 x 616
Weight 105/48 135/62 150/68 209/95 227/100 238/108 495/225 580/263
Input Connection Hardwire or Line Cord, Contact MajorPower.Com
Output Connection Hardwire or Receptacles, Contact MajorPower.Com
Typical Runtime (Min)
Full Load/Half Load
11 / 28 19 / 49 14 / 36 31 / 73 24 / 58 14 / 35 26 / 61 12 / 33
 
This Product is Highly Configurable - Please Contact MajorPower.Com
 
Visa MasterCard American Express Accepted MajorPower.Com: Powerware Ferrups Rackmount Series convert power from almost any AC source into computer grade power and eliminate harmful harmonic currents from entering a building's wiring, where they can disrupt computer operations Email This Page | Print Page | Terms & Conditions | About MajorPower.Com | Home