Powerware 9330 3-Phase UPS (10-40 kVA)

Maximum Availability - true double conversion online design, the proven technology that is used for the most mission-critical applications in the world. It's virtually impossible to find line-interactive, pseudo-online or any other kind of UPS other than double conversion online supporting 24/365 data centers, facilities, ISPs and major telecommunications installations.

Maximum Reliability- with Powerware Hot Sync, the award-winning, patented technology that achieves paralleling for redundancy and capacity (up to four modules) with no system-level single-point-of-failure. The preferred paralleling technology installed around the world with such major customers as ETrade, Colo.com, and Citibank, Powerware Hot Sync is now available in the 10-20 kVA range with the Powerware 9330.

Maximum Efficiency- the Powerware 9330's advanced design features the highest level of efficiency of any double conversion online UPS with 92% efficiency. That number increases to 97% with the debut of Powerware's Energy Optimizer* patented technology. No need to compromise reliability for efficiency with the Powerware 9330.

Maximum Performance - the Powerware 9330 delivers the highest performance by using Digital Signal Processing, true Pulse-Width-Modulation and maximum IGBT responsiveness. This provides easy setup, drift-free operation and a pristine output signal.

Global Services- Powerware service professionals provide round-the-clock monitoring, remote diagnostics, and on-site maintenance programs. More than just a material warranty, this is the most comprehensive service coverage available in the industry. Powerware Global Service provides our customers with peace of mind that potential downtime is prevented by proactive service and monitoring.

Powerware 9330 3-Phase UPS

Powerware 9330 3-Phase UPS Brochure Download

  9330 Specs
Powerware 9330 3-Phase UPS Pricing & Order
  Contact MajorPower.Com
for Specifications & Pricing
 

Powerware 9330 3-Phase UPS Features
  • Double Conversion
    • Online Technology provides reliable operation.
  • True Pulse Width Modulation (PWM) Technology & Digital Signal Processing
    • Increases overall system reliability & ensures perfect power on the output.
  • Energy Optimizer™ Mode
    • Increases operating online efficiency from 92% up to 97%.
  • High Efficiency
    • Increases overall system reliability, availability & performance & lowers overall cost of ownership.
  • Powerware Hot Sync™ Technology
    • A paralleling system that reduces the risks of traditional UPS'.
    • Eliminates connections that can fail and shut down a critical load.
    • Each UPS module operates independently of other modules to synchronize and support the load.
    • Permits the UPS to sample the output power over 3,000 times per second, adjusting and synchronizing accordingly.
    • Provides redundancy and capacity capability with system availability of 99.99% or greater.
  • Battery Management System
    • Includes DC Expert™, Temperature Compensated Charging & Battery Circuit Test.
  • Global Service
    • The most comprehensive service coverage available in the industry.
    • Round-the-clock monitoring, remote diagnostics, & on-site maintenance provide customer with peace of mind.
  • Intelligent Communications & Monitoring
    • An extensive array of communication gives the customer the ability to manage the Powerware 9330 locally or remotely via serial or network communications.
  • Built-in Control Area Network (CAN)
    • Assists in integrating peripherals & options, controllable from control panel.
    • Also reduces the internal wiring connections required therefore increasing overall system reliability.
  • Superior Cooling Design
    • Keeping critical components at the coolest possible levels ensures precise system operation and extends the life of system elements.
  • Environmental Capabilities
    • Efficiency combined with a well-engineered cooling design allows the UPS to reliably operate under extreme environmental conditions.
  • Internal Maintenance Bypass
    • Provides the ability to quickly perform maintenance on the critical load essential to maintaining overall systems availability and reliability.
  • Field Expandable
    • The Powerware 9330 provides our customers with a UPS that can grow with their system needs, whether it's to increase the kVA rating or to change system configurations from a single module system to a multi-module redundant or capacity system.
  • Comprehensive Communications and User Interface
    • A large LCD display and control panel is ergonomically situated for operator interface with the unit.
    • Soft keys help guide the operator through all menus and setups.
    • A dedicated microprocessor had been designed and engineered to provide sophisticated full featured monitoring, extensive alarm history, and additional communication options, including Ethernet, network links, and modems.
    • The intelligent firmware controls are designed to provide maximize protection to the critical load, and prevent operator actions that might jeopardize the load, such as the Smart Load Off button.
  • Generator Compatibility
    • Double-conversion online UPS technology is the only topology that can regulate frequency without transferring to battery.
  • Dual Feed Inputs
    • Standard separate rectifier & bypass feeds increase availability by providing input feeder buses.

Powerware 9330 3-Phase UPS Specifications
Electrical Input
Input Voltage 120/208 VAC, 3 phase + GND (rectifier); 120/208 VAC, 3 phase + N + GND (Bypass)
Voltage Range -15%, +10%
Frequency 50/60 Hz
Frequency Range 45 - 65 Hz
Input Power Factor > 0.96, Typical
Surge Protection Meets IEEE 587, Category A & B and EN 50091-2
Electrical Output
Output Voltage 120/208
Voltage Regulation Static: better than ±1%
Dynamic: better than Figure one of EN50091-3 (IEC 62040-3)
Voltage Distortion Less than 3% for 100% linear load
Less than 5% for nonlinear load when tested in accordance with EN50091-3
Frequency Regulation Synchronization: ±0.5, ±1.0, ±2.0 Hz, selectable
Free-running: ±0.005 Hz
Slew rate: 0.5, 1.0, 2.0, 3.0 Hz / sec, max selectable
Over Current 101 - 110% for 10 min (inverter)
111 - 125% for 1 min (inverter)
126 - 150% for 30 sec (inverter)
Environmental
Ambient Temperature Operation 0 to + 40ºC (32 to 104ºF)
Storage -20 to 70ºC (-4 to 140ºF)
Relative Humidity 95% maximum, non-condensing
Altitude 1500 meters (5000ft) at 40ºC ambient without load derating
Audible noise Less than 55dBA typical at 1 meter; in accordance with ISO 7779
Electrostatic Discharge Withstands 25kV without damage or disturbance to the load;
exceeds requirements of IEC 801-2
EMC Meets FCC Class A and EN50091-2 (IEC 62040-2)
Safety
  UL1778
CUL CAN/CSA C22.2 NO.107.1
EN 50091-1
Mechanical
Cable Entry Bottom rear, Bottom front
Cooling Filtered forced air with redundant fans
Access Front and top only required for service
Communications
Serial Port RS-232 communications port standard
Service Port RS-232 for service of equipment by qualified service personnel standard
Communication Cards Up to four optional cards can be installed in the UPS module at any time and provide the following connectivity:
  • Single RS-232 port
  • Multiple RS-232 ports
  • Ethernet Interface
  • SNMP Adapter
  • Modem Driver
Remote Communications Four input building alarm contacts
Two summary alarm contacts
Relay Interface Module Optional– provides five relay contacts

Powerware 9330 3-Phase UPS Model Selection Guide
Powerware 9330-20
Performance Characteristics
Model 10
10kVA/7kW
Model 15
15kVA/10.5kW
Model 20
20kVA/14kW
Input Voltage 208 480 480 600 400 208 480 480 600 400 208 480 480 600 400
Output Voltage 208 208 480 208 400 208 208 480 208 400 208 208 480 208 400
Input/Output Frequency (Hz) 60/50 60 60 60 50 60/50 60 60 60 50 60/50 60 60 60 50
Input Voltage Range
Minimum Volts 177 408 408 510 340 177 408 408 510 340 177 408 408 510 340
Maximum Volts 239 552 552 690 460 239 552 552 690 460 239 552 552 690 480
AC Input (With input filter)
Nominal Amps 22 10 10 8 12 32 14 15 11 18 43 19 20 15 23
Maximum Amps 29 30 13 30 16 40 41 18 41 22 51 52 23 52 28
AC Input (Without input filter)
Nominal Amps 22 10 10 8 12 32 15 15 12 18 44 19 20 16 24
Maximum Amps 30 13 14 11 16 41 18 19 14 22 52 23 23 18 28
Bypass Input
Nominal Amps 28 12 12 10 14 42 18 18 14 22 56 24 24 19 29
AC Output
Nominal Amps 28 28 12 28 14 42 42 18 42 22 56 56 24 56 29
10 Minutes 35 35 15 35 18 52 52 23 52 27 69 69 30 69 36
Battery
Nominal Voltage 288 288 288 288 288 288 288 288 288 288 288 288 288 288 288
Charge Voltage @ 25ºC 366 366 366 366 366 366 366 366 366 366 366 366 366 366 366
Charge Current (A) 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
Nominal Current (A) 27 28 29 28 29 41 42 43 42 43 55 56 57 56 57
Total Cell Count 144 144 144 144 144 144 144 144 144 144 144 144 144 144 144
System Efficiency
@100% Load 91% 88% 86% 86% 86% 92% 89% 87% 87% 87% 92% 90% 88% 90% 88%
@75% Load 90% 87% 85% 85% 85% 92% 89% 86% 86% 86% 92% 90% 88% 90% 88%
@50% Load 88% 85% 83% 83% 83% 91% 88% 85% 85% 85% 92% 90% 88% 90% 88%
Maximum Heat Dissipation
BTU/Hr. (x1000) 3.3 4.2 4.8 4.8 4.8 4.1 5.4 6.3 6.3 6.3 5.1 6.3 7.5 6.3 7.5
kcal/Hr. (x1000) 0.8 1.1 1.2 1.2 1.2 1.0 1.4 1.6 1.6 1.6 1.3 1.6 1.9 1.6 1.9
Inverter Efficiency
(Full Load)
93% 93% 90% 90% 90% 94% 94% 92% 92% 92% 94% 92% 90% 92% 90%
Physical Attributes (maximum)
Width 22 39 39 39 39 22 39 39 39 39 22 39 39 39 39
(1) Efficiency shown takes into account the output transformer for output voltages other than 208V.
(2) All accessories feature plug and play capability. Shipping pallet and packaging adds 50lbs per shipping unit.
(3) Options cabinet is required for voltages other than 208/208V.

Powerware 9330-40
Performance Characteristics
Model 25
25kVA/17.5kW
Model 30
30kVA/21kW
Model 35
35kVA/24.5kW
Model 40
40kVA/28kW
Input Voltage 208 480 480 600 208 480 480 600 208 480 480 600 208 480 480 600
Output Voltage 208 208 480 208 208 208 480 208 208 208 480 208 208 208 480 208
Input/Output Frequency (Hz) 60/50 60 60 60 60/50 60 60 60 60/50 60 60 60 60/50 60 60 60
Input Voltage Range
Minimum Volts 177 408 408 510 177 408 408 510 177 408 408 510 177 408 408 510
Maximum Volts 229 528 528 660 229 528 528 660 229 528 528 660 229 528 528 660
AC Input
Nominal Amps 55 24 24 19 66 29 29 23 77 34 34 27 82 38 38 30
Maximum Amps 70 30 30 24 83 36 36 29 97 42 42 34 100 48 48 38
Bypass Input
Nominal Amps 69 30 30 24 83 36 36 29 97 42 42 34 111 48 48 38
AC Output
Nominal Amps 69 69 30 69 83 83 36 84 97 97 42 96 111 111 48 112
10 Minutes 86 86 38 86 104 104 45 105 121 121 53 120 139 139 60 140
Battery
Nominal Voltage 288 288 288 288 288 288 288 288 288 288 288 288 288 288 288 288
Float Voltage @ 25ºC 366 366 366 366 366 366 366 366 366 366 366 366 366 366 366 366
Charge Current (A) 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
Nominal Discharge Current (A) 64 64 64 64 78 78 78 78 91 91 91 91 100 100 100 100
System Efficiency
@100% Load 92% 90% 88% 90% 92% 90% 88% 90% 92% 90% 88% 90% 93% 91% 89% 91%
@75% Load 91% 89% 87% 89% 92% 90% 88% 90% 92% 90% 88% 90% 92% 90% 88% 90%
@50% Load 89% 87% 85% 87% 91% 89% 87% 89% 91% 89% 87% 89% 92% 90% 88% 90%
.7pf@100% Load 97% 93% 91% 93% 96% 94% 92% 94% 96% 94% 92% 94% 96% 94% 92% 94%
Maximum Heat Dissipation
BTU/Hr. (x1000) 4.8 6.0 7.2 6.0 5.7 7.2 8.6 7.2 6.7 8.4 10.0 8.4 6.7 8.6 10.5 8.6
kcal/Hr. (x1000) 1.2 1.5 1.8 1.5 1.4 1.8 2.2 1.8 1.7 2.1 2.5 2.1 1.7 2.2 2.6 2.2
Inverter Efficiency
(Full Load)
93% 93% 91% 93% 93% 93% 91% 93% 93% 93% 91% 93% 94% 94% 92% 94%
Physical Attributes (maximum)
(W x H x D) (inches) 39x45x31 61x45x31 39x45x31 61x45x31 39x45x31 61x45x31 39x45x31 61x45x31
(1) Efficiency shown takes into account the output transformer for output voltages other than 208V.
(2) All accessories feature plug and play capability. Shipping pallet and packaging adds 50lbs per shipping unit.
(3) Options cabinet is required for voltages other than 208/208V.

Powerware 9330 3-Phase UPS Battery Runtime
In Minutes 9330-20 Series 9330-40 Series
Model 10 kVA
7 kW
15 kVA
10.5 W
20 kVA
14 kW
25 kVA
17.5 kW
30 kVA
21 kW
35 kVA
24.5 kW
40 kVA
28 kW
Base Unit 35 20 12 26 20 15 12
1 Battery Cabinet 95 50 35 49 38 33 26
2 Battery Cabinets 150 95 60 64 50 44 35
3 Battery Cabinets 200 130 95 98 76 62 49
4 Battery Cabinets 260 165 120 122 95 75 60
5 Battery Cabinets 320 215 150 146 114 100 79