| Phase Three Battery Chargers |
|
|
Phase Three "Smart" battery charging technology is now available in a wide range of power levels, allowing you to select the right size, features and flexibility you require for virtually any application from small recreational craft to large live-aboards, workboats and other commercial vessels. Phase Three chargers interact with batteries to put them through the optimum three stage charge process which provides for fastest recovery and ideal conditioning, maximizing battery performance and extending battery life.
A selector switch adjusts output voltage to adapt for gel-cell or flooded/AGM lead-acid batteries. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries' ambient temperature. All models are housed in a rugged stainless steel case, and the internal circuitry is polyurethane coated for maximum corrosion resistance.
|
|
 |
 |
| |
 |
Phase Three Specs |
|
|
 |
 |
 |
| Remote Indicator Panel
LED's indicate charger output stage. Button allows manual reinitialization of three stage charge cycle. Supplied with 25' cable and plug-in connector. Panel dimensions: 3" H x 4.75" W
Model: RP (Not available for all models)
|
Temperature Compensation Sensor
- 5 mV per cell per °C. Sensor supplied with 25' cable and plug-in connector
Model : TCS-12/24 shown (see below for applicable sensor depending on model)
|
DCE
DC Energy Monitor, reads Volts, Amps, Amp-Hours (See Digital Instruments)
|
|
|
 |
- Charge Characteristics
- 3 phase 'smart' charging: bulk, absorption, float.
- Internal terminals for optional equalization timer connection.
- Lead-acid/gel cell selector switch allows user to set optimum charge and float voltages based on battery type.
- Temperature compensation adjusts output voltage based on battery temperature via remote sensor (optional).
- High charge rate controlled by 8 hour timer and current sensing circuit, switching to float rate even if there is a high continuous demand on any battery bank, preventing an overcharging condition.
- Charge cycle timer is initialized when AC power is applied.
- Charges battery and powers load simultaneously.
- Multi-battery output, charges 3 banks on demand.
- Circuit Characteristics
- Conservative circuit design, switching semiconductors selected to withstand over 200% of nominal power level.
- Continuous duty rated to 50° C, with automatic high temperature power reduction.
- Operates on 115/230 VAC 50-60 Hz. Accepts wide variation on input, produces full output from utility or generator AC input.
- Fully functional as power supply without battery connected, well regulated stand alone power source if batteries fail.
- Low EMI/RFI emission , compatible with on-board electronics.
- Units may be wired in parallel for high power capability.
- Indicators/Monitors
- Ammeter reads full charge current.
- Remote panel (optional) indicates output condition and allows manual reset of charge phase.
- Remote meter (optional) digitally displays battery voltage up to 5 banks.
- Protection
- Stainless steel case with integral drip shield.
- Current limited won't overload when charging dead batteries.
- Variable speed thermally controlled fan.
- Automatic high temperature power reduction above 50° C.
- Circuit board polyurethane conformal coated for use in marine environments.
- Timer limits absorption charge interval to 8 hours, preventing overcharge.
- Certifications
- Ignition protected per USCG CFR 183.410.
- CE, UL, ABYC, FCC.
|
|
 |
|
12
Volt Models
|
| |
PT-7
|
PT-14
|
PT-25
|
PT-40
|
PT-70A
|
| Input
VAC (50-60 Hz.) |
88-132 or
176-264
|
85-264
|
90-132
or
180-264
|
85-135
or
170-270
|
90-264
|
| Input
Amps @ Full Load |
| @115
VAC Input |
2
|
2.8
|
6.5
|
8.5
|
12
|
| @
230 VAC Input |
1
|
1.4
|
4
|
4.3
|
6
|
| P.F.
Rating |
>.65
|
.95@230V
.98@115V
|
.7
|
.7
|
.95@230V
.98@115V
|
| Max
Output Amps |
|
@ 115 VAC
Input
|
7
|
14
|
25
|
40
|
64
|
|
@ 230 VAC
Input
|
7
|
14
|
25
|
40
|
70
|
|
Output Banks
|
2
|
3
|
3
|
3
|
3
|
| Battery
Capacity (Amp Hours) |
14-70
|
28-140
|
50-250
|
80-400
|
140-700
|
| Operating
Temp. Rating Ref. |
T-2
|
T-2
|
T-2
|
T-1
|
T-2
|
| Dimensions |
A-1
|
A-2
|
A-2
|
A-3
|
A-5
|
| Weight;
Lbs/Kg. |
3.2/1.5
|
8/3.6
|
8.2/3.7
|
12/5.5
|
15.2/6.9
|
| Operational
Temp. Sensor Model |
N/A
|
TCS-12/24
|
TCS-12/24
|
TCS-12/24
|
TCS-12/24
|
| Remote
Panel Model |
N/A
|
RP
|
RP
|
RP
|
RP
|
| Output
Indicator Ref. |
M-2
|
M-1
|
M-1
|
M-1
|
M-1
|
| Complience
Reference |
CG,
CE
|
CG,
CE
|
CG
|
UL,
CG, CE
|
CE
|
|
|
24
Volt Models
|
| |
PT-24-8
|
PT-24-13
|
PT-24-20
|
PT-24-40
|
PT-24-45F
|
PT-24-95F |
| Input
VAC (50-60 Hz.) |
85-264
|
90-132
or 180-264
|
85-135
or 170-270
|
90-264
|
207-253
|
207-253 |
| Input
Amps @ Full Load |
| @115
VAC Input |
2.8
|
6.5
|
8.5
|
12
|
N/A
|
N/A |
| @
230 VAC Input |
1.4
|
4
|
4.3
|
6
|
8
|
17 |
| P.F.
Rating |
.95@230V
.98@115V
|
.7
|
.7
|
.95@230V
.98@115V
|
.7
|
.7 |
| Max
Output Amps |
| @
115 VAC Input |
8
|
13
|
20
|
37
|
N/A
|
N/A |
| @
230 VAC Input |
8
|
13
|
20
|
40
|
45
|
95 |
| Output
Banks |
3
|
3
|
3
|
3
|
3
|
3 |
| Battery
Capacity (Amp Hours) |
16-80
|
26-130
|
40-200
|
80-400
|
90-450
|
180-950 |
| Operating
Temp. Rating Ref. |
T-2
|
T-2
|
T-1
|
T-2
|
T-3
|
T-3 |
| Dimensions |
A-2
|
A-2
|
A-3
|
A-5
|
A-4
|
A-6 |
| Weight;
Lbs/Kg. |
8/3.6
|
8.2/3.7
|
12/5.5
|
15.2/6.9
|
12.2/5.6
|
34.0/15.4 |
| Operational
Temp. Sensor Model |
TCS-12/24
|
TCS-12/24
|
TCS-12/24
|
TCS-12/24
|
TP
|
TP |
| Remote
Panel Model |
RP
|
RP
|
RP
|
RP
|
N/A
|
N/A |
| Output
Indicator Ref. |
M-1
|
M-1
|
M-1
|
M-1
|
M-3
|
M-3 |
| Complience
Reference |
CG,
CE
|
CG
|
UL,
CG, CE
|
CE
|
EN
|
EN, CE |
|
|
Case
Size Reference
|
| |
Inches
|
Centimeters
|
| Ref |
Height
|
Width
|
Depth
|
Height
|
Width
|
Depth
|
| A-1 |
10.5
|
5.0
|
2.8
|
26.7
|
12.7
|
7.1
|
| A-2 |
12.5
|
7.7
|
4.3
|
31.8
|
19.6
|
10.9
|
| A-3 |
14.1
|
9.5
|
4.0
|
35.8
|
24.1
|
10.2
|
| A-4 |
15.5
|
9.7
|
5.0
|
39.4
|
24.6
|
12.7
|
| A-5 |
15.7
|
9.8
|
6.7
|
39.9
|
24.9
|
17.0
|
| A-6 |
19.5
|
12.2
|
8.2
|
49.5
|
40.0
|
20.8
|
|
| Compliance References* |
| UL |
UL 1950 |
| CG |
USCG CFR 183.410 |
| EN |
EN 60335-1, EN 60335-2-29 |
| CE |
Carries the CE Mark |
| *
Numerous other Safety and EMC compliances may also apply. |
|
| Temperature
Rating References: |
| T-1 |
25°C
to +60°C; Derate linearly from 100% @ 50°C to 75% @ 60°C |
| T-2 |
10°C
to +60°C; Derate linearly from 100% @ 50°C to 80% @ 60°C
|
| T-3 |
20°C
to +50°C |
|
| Nominal
Output Voltages at Gel/Flooded Switch Settings |
| |
12
Volt Models
|
24
Volt Models
|
| Settings |
Charge
@ 50% load
|
Float
@ .5 amp load
|
Charge
@ 50% load
|
Float
@ .5 amp load
|
| Gel-Cell |
14.0
VDC
|
13.6
VDC
|
28.0
VDC
|
27.2
VDC
|
| Flooded/AGM |
14.2
VDC
|
13.4
VDC
|
28.4
VDC
|
26.8
VDC
|
| (Without
Temperature Compensation option installed or at 22.2°C (72°F)
with Temperature Compensation option installed) |
|
|
| Custom Applications- Contact MajorPower.Com |
| |