The MajorBCD 600 series Battery Chargers are capable of charging up to two independent banks of batteries at 12, 24, 32 or 48 VDC Products | Catalog | Contact Us
The MajorBCD 600 series Battery Chargers are capable of charging up to two independent banks of batteries at 12, 24, 32 or 48 VDC
Search:  
 
The MajorBCD 600 series Battery Chargers are capable of charging up to two independent banks of batteries at 12, 24, 32 or 48 VDC The MajorBCD 600 series Battery Chargers are capable of charging up to two independent banks of batteries at 12, 24, 32 or 48 VDC The MajorBCD 600 series Battery Chargers are capable of charging up to two independent banks of batteries at 12, 24, 32 or 48 VDC Tel: 514.369.4919 Fax: 514.369.4817

  Home > Chargers > MajorBCD 600 Series

Email this page The MajorBCD 600 series Battery Chargers are capable of charging up to two independent banks of batteries at 12, 24, 32 or 48 VDC
MajorBCD 600 Series

MajorBCD600

The MajorBCD600 has an all new single board design that incorporates state-of-the-art switchmode technology for unmatched efficiency and ultra-quiet operation.

Multiple stages of filtering reduce radiated or conducted noise to very low levels. The two-stage charging profile charges the batteries at a constant current equal to the maximum continuous output of the unit. When the battery voltages come up to the float voltage that the unit is set to, the current into the batteries will taper off as necessary to maintain the batteries at the float voltage.

The MajorBCD600 can be left permanently connected without fear of overcharge or damage to the batteries. The adjustable float voltage feature allows the unit to be used for any type of battery including lead acid and gel cell.

MajorBCD600 DC Battery Charger
MajorBCD600 Brochure Download
  MajorBCD600 Specs MajorBCD600 Specs
MajorBCD600 Pricing & Order
  MajorBCD600-32-12
MajorBCD600-32-24

MajorBCD600 Features
  • Adjustable Output Voltage
    • For charging standard or deep cycle lead-acid, VRLA or Gel cell type battery
  • Audible & Visual Indicators
    • For constant current, low input voltage, low output voltage & over-temperature
  • Extremely Rugged
    • Well suited for marine and other demanding environments
  • High Tolerance
    • For shock and vibration
  • Ultra-Quiet
    • Low EMI operation
  • Protection
    • Current limiting protection
    • Short circuit protection
    • Reverse input protection
    • Output over-voltage crowbar
    • Over temperature shutdown
  • Spark-Free Connection
  • Can be left Permanently Connected
  • Dry Contact Output Fail Relay
  • Warranty
    • 3 years parts and labour

MajorBCD600 Specifications
Mechanical & Environmental
Operating Temperature Range 0 - 40°C @ Maximum Output
Humidity 0 - 95°C @ Relative Humidity (non-condensing) with optional conformal coating
Audible Noise None Ødb @ 3 feet
Typical Service Life >10 years (87,600 hours)
Isolation Input-Case & Input-Output 1500 VDC; Output-Case 500 VDC
Dimensions (L x W x H) 9.1 x 7.8 x 4.3 in / 23.1 x 19.8 x 10.8 cm
Clearance 1 inch (2.5 cm) all around
Physical Marine-grade aluminum material, Black anodize / powder epoxy coat finish; 18-8 stainless steel fastenings; 4 contact output terminals
Weight 4.0 lbs / 1.8 kg
Warranty 3 years
Safety CSA/UL Pending

MajorBCD600 Model Selection Guide
Model MajorBCD600-32-12 MajorBCD600-32-24
Input Volts 20 - 45 30 - 45
Input Amps 40 40
Output Volts 13.6 ± 0.5 VDC 27.2 ± 0.5 VDC
Charging Amps 50 38
Output Crowbar 16.0 ± 0.5 VDC 32.0 ± 1.0 VDC
Input Fuses AGC 25 Amp x 2 AGC 25 Amp x 2
Output Fuses AGC 30 Amp x 2 AGC 25 Amp x 2
Low Input Voltage Alarm 10.5 VDC 10.5 VDC
Battery Banks 1 1
Stages 2 2
Battery Size (Amp Hours) 200 - 300 150 - 230
Transient Response < 1V for 15 Amp Surge < 1V for 15 Amp Surge
Efficiency > 85% @ Maximum Output > 85% @ Maximum Output
Duty Cycle Peak 20% for 10 min max;
Continuous 100% for 24 hours/day
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day
Line Load Regulation < ± 0.5% < ± 0.5%

MajorBCD605

The MajorBCD605 has an all new single board design that incorporates state-of-the-art switchmode technology for unmatched efficiency and ultra-quiet operation.

Applications include charging the compulsory battery on vessel's over 20 meters, temporarily brightening 12 volt headlights or work lights, increasing voltage into an automotive or marine ignition system for hotter spark and/or prevention of failures due to voltage drop during engine start, stabilizing 12V and 24 VDC power systems in marine, automotive or aeronautical environments and more.

MajorBCD605 DC Battery Charger
MajorBCD605 Brochure Download
  MajorBCD605 Specs MajorBCD605 Specs
MajorBCD605 Pricing & Order
  MajorBCD605-12-12
MajorBCD605-12-24

MajorBCD605 Features
  • Adjustable Output Voltage
    • For charging standard or deep cycle lead-acid, VRLA or Gel cell type battery
  • Audible & Visual Indicators
    • For constant current, low input voltage, low output voltage & over-temperature
  • Extremely Rugged
    • Well suited for marine and other demanding environments
  • High Tolerance
    • For shock and vibration
  • Ultra-Quiet
    • Low EMI operation
  • Protection
    • Current limiting protection
    • Short circuit protection
    • Reverse input protection
    • Output over-voltage crowbar
    • Over temperature shutdown
  • Spark-Free Connection
  • Can be left Permanently Connected
  • Dry Contact Output Fail Relay
  • Warranty
    • 3 years parts and labour

MajorBCD605 Specifications
Mechanical & Environmental
Operating Temperature Range 0 - 40°C @ Maximum Output; Derate Linearly 2.5% per °C from 40°C
Humidity 0 - 95°C @ Relative Humidity (non-condensing) with optional conformal coating
Audible Noise None Ødb @ 3 feet
Typical Service Life >10 years (87,600 hours)
Isolation Any Input or Output to Case 500 VDC; Input to Output Common Negative
Dimensions (L x W x H) 9.1 x 7.8 x 2.5 in / 23.1 x 19.8 x 6.4 cm
Clearance 1 inch (2.5 cm) all around
Physical Marine-grade aluminum material, Black anodize / powder epoxy coat finish; 18-8 stainless steel fastenings; 4 contact output terminals
Weight 4.0 lbs / 1.8 kg
Warranty 3 years
Safety CSA/UL Pending

MajorBCD605 Model Selection Guide
Model MajorBCD605-12-12 MajorBCD605-12-24
Input Volts 10.5 - 14 10.5 - 28
Input Amps 50 350
Output Volts 13.6 ± 0.5 VDC 27.2 ± 0.5 VDC
Charging Amps 42 21
Output Crowbar 16.0 ± 0.5 VDC 32.0 ± 1.0 VDC
Input Fuses AGC 30 Amp x 2 AGC 30 Amp x 2
Output Fuses AGC 25 Amp x 2 AGC 25 Amp x 2
Low Input Voltage Alarm 10.5 VDC 10.5 VDC
Low Output Voltage Alarm Programmed Output Voltage -2.5 VDC Programmed Output Voltage -2.5 VDC
Battery Banks 1 1
Stages 2 2
Battery Size (Amp Hours) 168 - 252 84 - 126
Transient Response < 1V for 15 Amp Surge < 1V for 15 Amp Surge
Efficiency > 85% @ Maximum Output > 85% @ Maximum Output
Duty Cycle Peak 20% for 10 min max;
Continuous 100% for 24 hours/day
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day
Line Load Regulation < ± 0.5% < ± 0.5%

MajorBCD610

The MajorBCD610 Battery Charger charges either 12, 24, 32 or 48 Volt batteries from a -48, 72, 110, 220 or 300 VDC power source. Other battery voltages up to 72 Volts are also available by special order.

The all new Current Mode switching design offers increased power and reliability in a compact package. Extra input and output filtering reduce EMI to extremely low levels.

The output voltage is easily adjusted 0.5 Volts above or below the standard output voltage to accommodate special charging requirements. 1 or 2 high quality analog meters can be added (factory option) to allow monitoring of charging current and charging voltage.

MajorBCD610 DC Battery Charger
MajorBCD610 Brochure Download
  MajorBCD610 Specs MajorBCD610 Specs
MajorBCD610 Pricing & Order
  MajorBCD610-110-12
MajorBCD610-110-24

MajorBCD610 Features
  • Transient Voltage Suppressor
  • Fully Isolated Design
  • Adjustable Output Voltage
    • For charging standard or deep cycle lead-acid, VRLA or Gel cell type battery
  • Audible & Visual Indicators
    • For constant current, low input voltage, low output voltage & over-temperature
  • Extremely Rugged
    • Well suited for marine and other demanding environments
  • Short Circuit Shutdown
  • User-Selectable 2 or 3 Stage Charging Profile
  • High Tolerance
    • For shock and vibration
  • Ultra-Quiet
    • Low EMI operation
  • Protection
    • Current limiting protection
    • Short circuit protection
    • Reverse input protection
    • Output over-voltage crowbar
    • Over temperature shutdown
  • Spark-Free Connection
  • Can be left Permanently Connected
  • Dry Contact Output Fail Relay
  • Warranty
    • 3 years parts and labour

MajorBCD610 Specifications
Mechanical & Environmental
Operating Temperature Range 0 - 40°C @ Maximum Output; Derate Linearly 2.5% per °C from 40°C
Humidity 0 - 95°C @ Relative Humidity (non-condensing) with optional conformal coating
Audible Noise None Ødb @ 3 feet
Typical Service Life >10 years (87,600 hours)
Isolation Input-Case & Input-Output 1500 VDC; Output-Case 500 VDC
Dimensions (L x W x H) 14.5 x 9.9 x 3.0 in / 36.8 x 25.1 x 7.6 cm
Clearance 1 inch (2.5 cm) all around
Physical Marine-grade aluminum material, Black anodize / powder epoxy coat finish; 18-8 stainless steel fastenings; 4 contact output terminals
Weight 7.6 lbs / 3.3 kg
Warranty 3 years
Safety CSA/UL Pending

MajorBCD610 Model Selection Guide
MajorBCD 610-48 610-72 610-100 610-250 610-300
Nominal Input 110 250 300 250 300
Input Voltage 100 - 140 230 - 280 280 - 360 230 - 280 280 - 360
Input Amps 3.4 1.5 1.3 1.5 1.3
Input Fuse (MDA) 4 3 2 3 2
Noise on Input < 25 mV < 25 mV < 25 mV < 25 mV < 25 mV

Nominal Output Voltage 12 24 32 48
Output Voltage 13.6 ± 0.05 27.2 ± 0.05 36.3 ± 0.05 54.4 ± 0.05
Absorption Voltage 14.4 28.8 38.4 57.6
Charging Amps 40 20 15 10
Absorption to Float 4.0 Amps 2.0 Amps 1.5 Amps 1.0 Amps
Output Fuses (ATC) ATC 40 x 2 ATC 30 x 2 ATC 20 x 2 ATC 15 x 2
Battery Banks 1 or 2 1 or 2 1 or 2 1 or 2
Output Adjustment ± 0.5 ± 0.5 ± 0.5 ± 0.5
Battery Size (AH) 160 - 240 80 - 120 60 - 90 40 - 60
Output Crowbar 16.0 ± 0.5 V 32.0 ± 1.0 V 42.7 ± 1.3 V 63.9 ± 2.0 V
Output Ripple & Noise < 50 mV < 50 mV < 50 mV < 50 mV
Transient Response < 2 V for 50% Surge < 2 V for 50% Surge < 2 V for 50% Surge < 2 V for 50% Surge
Line Load Regulation < ± 0.5% < ± 0.5% < ± 0.5% < ± 0.5%
Duty Cycle Peak 20% for 10 min max;
Continuous 100% for 24 hours/day
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day
Peak 20% for 10 min max;
Continuous 100% for 24 hours/day
Efficiency > 75% @ Maximum Output > 75% @ Maximum Output > 75% @ Maximum Output > 75% @ Maximum Output
Stages 2 or 3 2 or 3 2 or 3 2 or 3

Custom DC Battery Charger Application - Contact MajorPower.Com
 
Visa MasterCard American Express Accepted battery charger, battery chargers, chargers, charger, bcd, bcd series, systems battery chargers, battery volts, DC source       Email This Page | Print Page | Terms & Conditions | About MajorPower.Com | Home
battery charger, battery chargers, chargers, charger, bcd, bcd series, systems battery chargers, battery volts, DC source sales@majorpower.com
copyright 2002 battery charger, battery chargers, chargers, charger, bcd, bcd series, systems battery chargers, battery volts, DC source