MajorPower.Com: Online suppliers of power inverters, battery chargers, UPS and power supplies. Specializing in frequency, phase and DC converters, voltage, surge protection, telecomunications power systems Product List | Order | Contact Us
MajorPower.Com: Online suppliers of power inverters, battery chargers, UPS and power supplies. Specializing in frequency, phase and DC converters, voltage, surge protection, telecomunications power systems
Search:  
 
MajorPower.Com: Online suppliers of power inverters, battery chargers, UPS and power supplies. Specializing in frequency, phase and DC converters, voltage, surge protection, telecomunications power systems MajorPower.Com: Online suppliers of power inverters, battery chargers, UPS and power supplies. Specializing in frequency, phase and DC converters, voltage, surge protection, telecomunications power systems MajorPower.Com: Online suppliers of power inverters, battery chargers, UPS and power supplies. Specializing in frequency, phase and DC converters, voltage, surge protection, telecomunications power systems Tel: 514.369.4919 Fax: 514.369.4817

   Home > Battery Index > Telecom Series

Email this page MajorPower.Com: Online suppliers of power inverters, battery chargers, UPS and power supplies. Specializing in frequency, phase and DC converters, voltage, surge protection, telecomunications power systems
Telecom Battery Series

"TELECOM" TL and CSL Batteries are the ideal choice for Telecommunication applications which require a reliable, compact and affordable solution. Since these batteries are low-gassing they require no special ventilation. Additionally, a compact design makes them perfect for low maintenance and space restricted applications.

 
  • Ten-year design life.
  • A recognized component of U.L.
  • Valve regulated lead acid battery (VRLA).
  • Absorbed glass mat technology (AGM) with gas recombination greater than 99%.
  • Operates at a low internal pressure.
  • Never needs watering, minimal maintenance.
  • 99.7% pure lead calcium grids.
  • Shock absorbant thick wall polypropylene cases.
  • *Cases are flame retardant, meet U.L. 94. V0 requirements, and have an oxygen index greater than 28%.
  • Cold forged non-porous terminal bushings, eliminate post leakage.
  • Thermally welded cover to case bond, eliminates both acid and electrical leaks.
  • Over-sized, through the partition inter-cell welds provide low resistance connections, with minimal power loss.
  • Each cell has a low pressure safety release venting system, recognized per U.L. 924.
  • Measured high vacuum acid fill, reduces electrical variability between cells.
  • 100% recyclable materials.
  • Options:
    • Terminal covers and custom inter-connecting battery cables. (Terminal covers are standard on the CSL models).
  • **No transport restrictions:
    • Surface transport. Classified as non-hazardous material as relates to DOT-CFR Tile 49 part 171-189.
    • Water transport. Classified as non-hazardous materials as per IMDG amendment 27.
    • Air transport. Complies with IATA / ICAO, special provision A67.

Operating Temperature Range
Discharge -40ºF (-40ºC) to +140ºF (60ºC)
Charge -4ºF (-20ºC) to +122ºF (50ºC)
Ideal Operating Temp Range +68ºF (20ºC) to +77ºF (25ºC)
Charging Voltage
Float operation 2.25 to 2.30 V.P.C.
Cycling operation 2.35 V.P.C.
Charge voltage temperature compensation factor Temperature correction factor for float voltage charge is to add 1.7mV/ºF (3mV/ºC) below 77ºF (25ºC) and subtract 1.7mV/ºF (3mV/ºC) above 77ºF (25ºC). This correction factor only applies to temperatures between 32ºF (0ºC) and 104ºF (40ºC)
Maximum charging currents
Partially discharged Self limiting
80% to 100% discharge C/4 amperes
Storage time from a fully charged condition 6 months at 77ºF (25ºC) (less at higher temperatures)

"Telecom" Series - Traditional Design
Battery Model # Volts Nominal AH@8 hrs to 1.75VPC Dimensions
L x W x H**
Weight
TL-1230 12 29 7.71 x 5.18 x 7.19"
196 x 865 x 183mm
26.7lbs
(12.1kg)
TL-1245 12 45 8.61 x 5.29 x 8.17"
219 x 134 x 208mm
35.3lbs
(16kg)
TL-1270 12 68 10.20 x 6.57 x 9.03"
259 x 167 x 229mm
60.6lbs
(27.5kg)
TL-1280 12 82 12 x 6.57 x 9.21"
305 x 234 x 245mm
71.9lbs
(32.7kg)
TL-1295 12 96 13.54 x 6.76 x 9.02"
344 x 172 x 229mm
80.6lbs
(36.7kg)
TL-12120 12 118 13.54 x 6.76 x 11.02"
344 x 172 x 280mm
99.4lbs
(45.2kg)
TL-6196 6 193 10.71 x 7.38 x 10.93"
272 x 187 x 278mm
81.5lbs
(37kg)
TL-2480 2 480 10.71 x 7.38 x 10.93"
272 x 187 x 278mm
87lbs
(39.5kg)

"Telecom" Series - Front Access Design
Battery Model # Volts Nominal AH@8 hrs to 1.75VPC Dimensions
L x W x H**
Weight
CSL-1280 12 82 21 x 4.28 x 9.63"
534 x 109 x 245mm
74lbs
(33.6kg)
CSL-12100 12 100 21 x 4.28 x 9.63"
534 x 109 x 245mm
84lbs
(38.2kg)
CSL-12170 12 170 20.9 x 8.7 x 10.1"
534 x 221 x 257mm
152lbs
(69.1kg)
  * All batteries have "L" type lead terminals except the SLF types which have a drop terminal with copper insert.
** Height is to the top of the terminal.

Custom Applications - Contact MajorPower.Com
   
Visa MasterCard American Express Accepted MajorPower.Com: Online suppliers of power inverters, battery chargers, UPS and power supplies. Specializing in frequency, phase and DC converters, voltage, surge protection, telecomunications power systems       Email This Page | Print Page | Terms & Conditions | About MajorPower.Com | Home
MajorPower.Com: Online suppliers of power inverters, battery chargers, UPS and power supplies. Specializing in frequency, phase and DC converters, voltage, surge protection, telecomunications power systems sales@majorpower.com
copyright 2002 MajorPower.Com: Online suppliers of power inverters, battery chargers, UPS and power supplies. Specializing in frequency, phase and DC converters, voltage, surge protection, telecomunications power systems